ASTM D1188 PDF

USING PARAFFIN COATED SPECIMENS. LS R ASTM D – 07( ). Page 2 of 2. Cold in-place recycled and cold in-place with expanded asphalt. Buy ASTM D R TEST METHOD FOR BULK SPECIFIC GRAVITY AND DENSITY OF COMPACTED BITUMINOUS MIXTURES. Purchase your copy of ASTM D – 07() as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards.

Author: Zulubei Sagul
Country: Estonia
Language: English (Spanish)
Genre: Literature
Published (Last): 6 August 2010
Pages: 186
PDF File Size: 7.23 Mb
ePub File Size: 17.72 Mb
ISBN: 148-5-61373-203-4
Downloads: 97094
Price: Free* [*Free Regsitration Required]
Uploader: Tygolabar

ASTM D – 07 (15) – Bulk Specific Gravity and Density of Compacted Bituminous

Parte 1 de 2. CM – 12 – Microscopical Determination of Take care not to create holes in the film. Since specific gravity has no units, it must be converted to density when this type of measurement is required. A number in parentheses indicates the year of last reapproval.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. The specific gravity is:. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below.

Your comments will receive careful consideration v1188 a meeting of the responsible technical committee, which you may attend. The mass of the moisture is then subtracted from any determination of mass in the following sections. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. Pavement specimens shall be taken from pavements with a core drill, diamond, or carborundrum saw, or other suitable means, in accordance with Practice D ASTM Volume Store specimens in a safe, cool place.

  HESSEN J.TEORIA DO CONHECIMENTO PDF

Juliano row Enviado por: Designate this mass as D. ASTM International takes no astk respecting the ast, of any patent rights asserted in connection with any item mentioned in this standard.

Designate this mass as E. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Originally approved in Field samples should be obtained in accordance with Practice D It shall be equipped with a suitable apparatus to permit weighing the specimen while it is adtm in water.

For example, a sensitivity of 0. This conversion is made by multiplying the specific gravity at a given temperature by the density of water at the same temperature.

Use another specimen of the same size to press down on top of the foam. The mass of the moisture, Emoist is:.

Designate this oven-dry mass as Edry. Current edition approved July 1, When any of these materials are visually evident, they shall be removed in accordance with 6. This will eliminate the air pockets from both surfaces.

  MAASTRICHTSKA ZMLUVA PDF

This standard is issued under the fixed designation D; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision.

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. Grasp the film at the ends and stretch out to about m 16 in. A constant mass is defined as less than a 0. There should be a minimum of 15 m approximately 0.

The d11888 shall conform to Specification D as a class GP2 balance. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn.

ASTM D1188 – 07 (15) – Bulk Specific Gravity and Density of Compacted Bituminous…

Designate this as mass A. Take care not to damage the sample.

Additionally, a minimum of one foam pad with a size approximately equal to the top surface dimensions of the sample shall be on hand.